PlantWise Help

PlantWise Router Menu

The Router menu contains two commands that control the router itself.

SettingDescription
Route Opens the AutoRouter Control dialog to route and/or reroute pipelines.
Unroute Removes all pipe routes. Before unrouting, the AutoRouter prompts you for confirmation.
Pipeway Header Sequence Opens the Pipeway Header Sequence dialog. This dialog allows the squencing of header pipes on pipeways.
AutoNozzle All Activates the nozzle placement rules for all placed equipment in the model. This command differs from the AutoNoz command in the Plant toolbox in CAD, which only activates the nozzle placement for a single piece of equipment (see Plant Toolbox).
Auto Flange All Places flanges on all pipes that do not already have flanges. A flange will be placed at both the upstream and downstream segment of a pipeline based on the Project Setup settings for Auto Flange.
There five Project Setup settings for Auto Flange. Three are simple Yes/No values that control whether or not a flange is to be placed at:
  • Boundaries
  • Control Valves
  • Tees
The other two Project Setup variables control which User Defined Inline is to be placed on the upstream and downstream segments of the pipes.
Note: Any User Defined Inline may be specified and there is no error checking if the UDI is actually a flange, or if it even exists.
The PlantWise main dialog will display
"Finished Auto Flange"
after all of the flanges have been added.
Auto Reducer All Scans all pipelines and insert a reducer in the connectivity record when it finds an inconsistency in the diameters.
AutoLoop Opens the Pipeway Loop Editor.
Freeze/Thaw Opens the Freeze/Thaw Control dialog.