STAAD.Pro Help

D8.B.9 Member Selection

STAAD.Pro is capable of performing design operations on specified members. Once an analysis has been performed, the program can select the most economical section, that is, the lightest section, which satisfies the applicable code requirements.

The section selected will be of the same type (I-Section, Channel etc.) as originally specified by the user. Member selection may be performed with all types of steel sections listed in D8.B.12 Built-in Indian Steel Table and user-provided tables. Selection of members whose properties are originally provided from user-specified table is limited to sections in the user-provided table.

Member selection cannot be performed on members whose cross sectional properties are specified as PRISMATIC.

The process of MEMBER SELECTION may be controlled using the parameters listed in D8.B.4 Design Parameters. The parameters DMAX and DMIN may be used to specify member depth constraints for selection. If PROFILE parameter is provided, the search for the lightest section is restricted to that profile. Up to three (3) profiles may be provided for any member with a section being selected from each one.

メンバー選択の一般的な情報については、「 D1.B.1.4 メンバーの選定」を参照してください。メンバー選択コマンドの仕様の詳細については、「TR.49.1 メンバー選定の設定」を参照してください。