To Place Free Form Nozzle
- Select the Free Form Nozzle option from the Equipment ribbon.
- Optional: If the Spec Record Selection dialog displays, select a nozzle from the list and click OK.
- Select a Placement Point option from the Place Component dialog.
- Click the Design Values tab and select either New Nozzle or Nozzle Locator as the Placement Type.
- Use the remaining Property fields to define any additional nozzle properties.
- Pick a point on an equipment component. (This nozzle type can also be placed on an existing Piping component such as a flange if using the Main Port.) An outline of the component displays.
- Pick a point to define the direction and complete the placement process. By default, the placement command remains active until another command is selected.
- Right-click to terminate the command.