STAAD.Pro Help

M. To add wall data area to an IS1893 2016 seismic definition

To add the first story wall area data for an IS 1892 2016 seismic load definition, use the following procedure.

You must create a reference load case containing the load items to be used as weights in the seismic load. Refer to M. To create a reference load for details.
The wall data area is only required for an IS 1893 2016 seismic load applied to a buiding of structure type 4 (i.e., reinforced concrete structural walls). This data is ignored for any other code or building type.
  1. In the Loads & Defintions dialog, select the seismic defintion to which you want to add weights and then click Add. The Add New: Seismic Definitions dialog opens.
  2. Select the Wall Area tab in the Add New: Seismic Definitions dialog.
  3. For each wall in the global X direction in the first story above ground, type the Width and Length of the wall in plan.
  4. For each wall in the global Z direction in the first story above ground, type the Width and Length of the wall in plan.
  5. Click Add.
  6. Either:

    To close the dialog, click Close.

    or

    To proceed to manually add weight data, select one of the weight types. See M. To add weight items to a seismic load definition for details.

    or

    To proceed to use a reference load for weight data, select the Reference Load tab. See M. To add weight by a reference load to a seismic load definition for details.