STAAD.Pro Help

T.2 Specifying Loads

Five load cases are to be created for this structure. Details of the individual cases are explained at the beginning of this tutorial.

The STAAD input file commands generated are:

UNIT METER KG
LOAD 1 DEAD LOAD
SELFWEIGHT Y -1
MEMBER LOAD
2 5 UNI GY -400
LOAD 2 LIVE LOAD
MEMBER LOAD
2 5 UNI GY -600
LOAD 3 WIND LOAD
MEMBER LOAD
1 UNI GX 300
4 UNI GX 500
LOAD 4 DEAD + LIVE
REPEAT LOAD
1 1.2 2 1.5
LOAD 5 DEAD + WIND
REPEAT LOAD
1 1.1 3 1.3