STAAD.Pro Help

D5.D.3.2 Clause 6.1 – General

The partial safety factors will use the following values:

  • Resistance of cross-sections, γM0 = 1.0
  • Resistance of members to instability, γM1 = 1.0
  • Resistance of cross sections to tension, γM2 = 1.25

The design function in STAAD.Pro sets these values as the default values for the D-NA (NA 3 is specified).

Note: You can change these values through the GM0, GM1, & GM2 design parameters. Refer to D5.C.6 Design Parameters