Name
|
The name is a reference to a cross link, where the same name can be used in different cross sections.
|
Selection
|
The appropriate link segment can be activated or de-activated at the segment points.
|
Position
|
The connection can be defined before or after the segment point (important for cross section discontinuities, at the segment begin and end).
|
Subdivide at intermediate nodes from base segment cross-section |
When this new option enabled, program will calculate all parts which are
between link start/end parts and it will generate additional beam
elements. If this option disabled, program will create a single beam
element for entire link.
Note: When a cross member is added, program automatically will place
beam numbers:
- If Automatic numbering schema is enabled, then the program
will get next available beam number.
- If Automatic numbering schema is disabled, then program will
compute maximum beam number used in project and apply and
offset of 100 to generate a new beam number for link
segment.
|