From, To, Step
|
Element series to be loaded |
Assembly
|
Alternative to load assignment via element series: Name of the assembly to be loaded. The specified load is applied to every element of the specified assembly. |
Alpha
|
Temperature expansion coefficient Default: Value from material the property table
|
DT-G
|
Uniform temperature difference applied to all selected elements. |
DT-Y
|
Temperature difference in local y-direction (mostly vertical). Sign: Positive value is a temperature raise in positive y direction.
|
H-Y
|
Reference depth value in y direction for calculating the gradient DT-Y / H-Y. Default: CS depth. In this case, DT-Y is the temperature difference between top and bottom edge of the CS. (No default if QS values defined instead of QS geometry).
|
DT-Z
|
Temperature difference in local z-direction (mostly horizontal). Sign: Positive value is a temperature raise in positive z direction.
|
H-Z
|
Reference width value in z direction for calculating the gradient DT-Z / H-Z. Default: CS width. In this case, DT-Zis the temperature difference between right and left edge of the CS. (No default if QS values defined instead of QS geometry).
|