Traveler weight |
Weight of the traveler (to be given with positive sign): Is used for the load case "traveler" (Single element load (Force + Moment) - FSGM). For Load explination, see the online help in RM Bridge. |
Gamma |
Specific weight for the load case of the wet concrete. If no input is given, the value defined in the material table in the Analyzer is used (typically 25 kN/m3). |
Ecc.1 / Ecc.2 |
Input data for the load cases "Traveler" and "Wet concrete" (element weight as nodal load at begin / end of segment - FSEGB and FSEGE). For Load explination, see the online help in RM Bridge. |
Ecc. 3 |
Additional optional input for the traveller load. Offset of the center of gravity of the traveller load from the central axis of the two anchor points. |
Prefix |
Prefix for the names of the load cases, load sets, and stages in the Analyzer. When left empty, no prefix is used. The same prefix must be used for all schedule groups. |
First stage |
Number of the first stage (e.g., Prefix = STG + First stage = 1 creates the stage names "STG_1", "STG_2", "STG_3", …). |
Summation load case |
Name of the summation load case for the calculation in the Analyzer; load case, which the results of each stage are added to and are saved as [Summation load case]-[Prefix]_Stage number (e.g., LC-SUM-STG_1. A single summation load case for all schedule groups is created. |
Blisters |
Opens the Blisters dialog, which is used for the consideration of blister weights. |
Cross Girders |
Opens the Blisters dialog, which is used for the consideration of cross girder weights. |
LC-Names |
The names for the load cases "Self weight", "Wet concrete", "Traveler", "Pre-stressing", and "Creep and Shrinkage" can be entered here (or be changed respectively). The default names are SW (Self weight), WC (Wet concrete), TR (Traveler), PT (Pre-stressing), and CS (Creep and shrinkage), respectively. These are needed for the load case and load set definitions and for the load case calculations in the Analyzer (Action Calc), as well as for the load info for the load manager. |
Camber |
By entering a label the action DoCamber can be added to the schedule of the Analyzer, in fact optionally at the begin and the end of the stage, after the calculation of the load case "Pre-stressing", after the load case "Traveler" and after the load case "Wet concrete". For more detailed information for the command DoCamber see online-help of RM Bridge.
|
Plots |
There is the possibility of inserting the command for the generation of a plot within the schedule actions in the Analyzer (Action DoPlot). The respective name of the Plot container and the Plot profile which are necessary for this action can be given here. The name of the output file is PL-[Plot profile]-[Prefix]_[Stage number] (e.g., PL-Vy-STG_01). |
RMSets |
Input option for the generation of an RmSets (DgmSet) within the schedule in the Analyzer. The name of the output file is Dgm-[RMSet]-[Prefix]_[Stage number] (e.g., Dgm-Vy-STG_01). |
|
Opens the Fill form dialog, which is used to automatically generate the schedule. |