Wall <material> Live Load Reduction dialog
Used to assign a live load reduction factor percentage to one or more walls.
Opens when either:
- is selected
- the On-Grid tool is selected from the Layout Wall dynamic toolbar
When a Wall is initially modeled, it is given the default Live Load Reduction assignment, which is to calculate and use the value allowed according to the building code selected. Therefore, this command need not be selected unless an alternate maximum Live Load Reduction factor is desired, or to clear any previous assignment made.
Setting | Description |
---|---|
Single | Click the target cursor on the wall for which you wish to specify the maximum Live Load Reduction factor. |
Fence | Fence an area in which all walls will be assigned the specified maximum Live Load Reduction factor. |