Assign Pile Geometry
In order for the program to check the pile design, you must provide the unfactored capacity of the piles and the layout which should be used.
- Select .
- For the Label type 14in.
- Set the Diam to 14 (300)
- Compression capacity to 120 (500)
- Tension Capacity to 20 (100)
- Shear capacity to 5 (25)
- Click [Add].
- Click [OK].
To assign the pile cap geometry: