RAM Structural System Help

Assign Pile Geometry

In order for the program to check the pile design, you must provide the unfactored capacity of the piles and the layout which should be used.

  • Select Assign > Edit Piles.
  • For the Label type 14in.
  • Set the Diam to 14 (300)
  • Compression capacity to 120 (500)
  • Tension Capacity to 20 (100)
  • Shear capacity to 5 (25)
  • Click [Add].
  • Click [OK].

To assign the pile cap geometry:

  • Select Assign > Geometry > Pile Cap.
  • Select the 14in pile on the left and the 3 Pile Group on the right
  • Leave the other options in the default position and click [All].