RAM Structural System Help

Assign - Sway-Sensitive Design Method (BS5950:2000)

For BS5950:2000, selecting the Assign > Sway > Sensitive Method opens the Sway-Sensitive Design Method dialog. From this dialog the engineer can specify the design approach to be applied to the member for a specific axis. That is, per BS5950-2.4.2.7 the user can designate to use the Effective Length approach per 2.4.2.7a. or the Amplified Sway Approach per 2.4.2.7b. For the amplified sway approaches the user can designate to have the program calculate kamp for each load combination or to use a specified value.

For the Amplified Sway Approach if the Calculate (Per Load Combination) option is selected then the program will calculate the lateral story drift at the position of each member being designed (for all floors), for only the factored notional loads in the load combination. For that specific combination the drifts are then used to calculate λcr per BS5950 2.4.2.6 and in turn are used to calculate kamp per 2.4.2.7b.1. Note that the user will need to create and analyze notional load cases to make use of this option. Refer to the technical section of the manual for more information on calculating λcr for load combinations.

The sway-sensitive design method criteria are only used by the BS5950:2000 steel design codes and only if p-delta analysis was not performed.

The assignment made for each member can be displayed on the screen by selecting the associated 'Sway-Sensitive' display property from the View-Members dialog.

Select the axis checkbox to make an assignment to a specific member axis. After the appropriate values are specified the engineer can assign the criteria to a single member (click on Single), to multiple members (click on Fence) or to all members (click on All). If Single is clicked the dialog will close and a target cursor will be made available. Click on each section that you would like the criteria to apply to. If Fence is clicked the dialog will close and a fence cursor will be made available. Click and drag a rectangle around all the sections that you want the criteria assigned to. Note that the criteria are only assigned to steel members.

To view what sway sensitive design method is assigned to each member select the appropriate option from the View-Members Dialog.