PlantWise Help

Updating Pipe Sizes

The suggested workflow is:
  • Create a new model.
  • Import the process data from an FSR.
  • Layout the model adding pipeways as needed.
  • Route the model.
  • Save the PlantWise model.
  • Export the pipes through an FSR.
  • Close the PlantWise model.
  • Size the pipes and export the FSR once more.
  • Open the PlantWise model.
  • Update the pipe sizes in PlantWise by selecting Update Pipe Size from FSR:
    • PlantWise -> Model -> Import -> EC Data -> Update Pipe Size from FSR (shown below).
    Note: Only one EC data import can be performed during a model session. To update the pipe sizes, the model must be saved and reopened before the pipe sizes can be updated.