PlantWise Help

EC Data (Engineering Content)

SettingDescription
Default Pipe Class The pipe class that will be used when there is no pipe class specified when importing data using any of the EC data exchange methods.
  • Constant: *EC-Import-Default-Pipe-Class*
  • English: “A2A”
  • Metric: “A2A”
Default Pipe Commodity The commodity that will be used when there is no commodity specified when importing data using any of the EC data exchange methods.
  • Constant: *EC-Import-Default-Commodity*
  • English: “Air”
  • Metric: “Air”
Default Pipe Nominal Diameter The nominal diameter that will be used when an imported pipe does not have a diameter specified.
  • Constant: *EC-Import-Default-Pipe-Diameter*
  • English: 1.0
  • Metric: 25.0
EC Data import program The program that will be used to import EC data directly from another program.
  • Constant: *EC-IMPORT-PROGRAM*
  • English: PWAxsysECData.exe
  • Metric: PWAxsysECData.exe
EC Data import program path The fully qualified path to the program that is to be used to import data directly from another program.
  • Constant: *EC-IMPORT-PROGRAM-PATH*
  • English: "C:\\Program Files\\Bentley\\PlantWise CONNECT Edition\\PlantWise\\assemblies\\ECFramework"
  • Metric: "C:\\Program Files\\Bentley\\PlantWise CONNECT Edition\\PlantWise\\assemblies\\ECFramework"
i-model Schema file name The Open Plant schema to use when publishing i-models. It MUST include “.ECSchema.xml”.
  • Constant: *i-model-Schema*
  • English: "OpenPlant_3D.01.08.ecschema.xml"
  • Metric: "OpenPlant_3D.01.08.ecschema.xml"
Open Plant Schema file The Open Plant Schema to use when importing/exporting EC data. It MUST include “.ECSchema.xml”.
  • Constant: *EC-OpenPlant-Schema*
  • English: "OpenPlant.01.08.ecschema.xml"
  • Metric: "OpenPlant.01.08.ecschema.xml"
Create default Nozzles Tells PlantWise to create and place nozzles on new instances of an equipment class that has default nozzles memorized. If this parameter is set to No, nozzles will not be created or placed when new instances are added to the model.
  • Constant: *PW-USE-MEMORIZED-NOZZLES*
  • English: Yes
  • Metric: Yes
Default Equipment Text Level Controls what level in CAD, equipment text is drawn on when no level is specified in the equipment geometry.
  • Constant: *PBAR-EQUIPMENT-TEXT-LEVEL*
  • English: “equipment”
  • Metric: “equipment”
Default Equipment Text Size Specifies an absolute value, in main units, for the text height. All equipment text will be drawn at this height. If the value is 0.0, the default, the text height will be based on the equipment’s geometry language specification.
  • Constant: *PBAR-EQUIPMENT-TEXT-SIZE*
  • English: 0.0 in
  • Metric: 0.0 mm