PlantWise Help

Export Format Examples

(alignment and truncation have been added to improve readability)

Single Origin, Single Terminus

Here is an example of single-origin, single-terminus pipelines.
(10-100 4.0 S2S DW none 0.0
10-T-100/B1 4.0 480.4 6912.6 1308.0
elbow 4.0 484.6 6912.6 1308.0 490.6 6912.6 1308.0 490.6 6912.6 1302.0
elbow 4.0 490.6 6912.6 1280.3 490.6 6912.6 1286.3 496.6 6912.6 1286.3
elbow 4.0 561.2 6912.6 1286.3 555.2 6912.6 1286.3 555.2 6912.6 1280.3
elbow 4.0 555.2 6912.6 1244.3 555.2 6912.6 1250.3 555.2 6906.6 1250.3
elbow 4.0 555.2 6808.0 1250.3 555.2 6814.0 1250.3 555.2 6814.0 1244.3
elbow 4.0 555.2 6814.0 1215.6 555.2 6814.0 1221.6 555.2 6808.0 1221.6
ecc_reducer 3.0 555.2 6808.0 1221.6 555.2 6804.0 1222.1
10-P-101/IN 3.0 555.2 6800.5 1222.1)
Line 10-100 starts and ends at equipment nozzles. It has 6 elbows and an eccentric 4x3 reducer from (555.2 6808.0 1221.6) to (555.2 6804.0 1222.1).

Multiple Origins – Group of 2

Here is an example of multiple-origin pipelines.
(10-200 4.0 N2S LPC none 0.0 10-V-101/B2 4.0 1310.0 7042.9 1290.0
	elbow 4.0 1310.0 7045.9 1290.0 1310.0 7051.9 1290.0
			1310.0 7051.9 1284.0
	elbow 4.0 1310.0 7051.9 1244.3 1310.0 7051.9 1250.3
			1310.0 7057.9 1250.3
	elbow 4.0 1310.0 7159.3 1250.3 1310.0 7153.3 1250.3
			1310.0 7153.3 1244.3
	(10-200-1 10-P-104A/IN 4.0 1370.0 7162.3 1222.1
		elbow 4.0 1370.0 7159.3 1222.1 1370.0 7153.3
			1222.1 1364.0 7153.3 1222.1
		tee 10-200 4.0 1314.125 7153.3 1222.1 1310.0 7153.3 1222.1
			1305.875 7153.3 1222.1
		elbow 4.0 1256.0 7153.3 1222.1 1250.0 7153.3
			1222.1 1250.0 7159.3 1222.1
		10-P-104B/IN 4.0 1250.0 7162.3 1222.1)
	4.0 1310.0 7153.3 1226.2)
Line 10-200 starts at vessel nozzle 10-V-101/B2 and goes to a header to a pair of pumps (10-P-104A and 10-P-104B). The main line ends at the header line (10-200-1), which has an elbow, a tee, and another elbow.

Multiple Origins – Group of 3

(10-204 2 N2S LPC IS 1.0 10-V-101/B1 2.0 1342.4 7010.5 1288.2
	elbow 2.0 1391.7 7010.5 1288.2 1394.7 7010.5 1288.2
		1394.7 7010.5 1285.2
	elbow 2.0 1394.7 7010.5 1249.2 1394.7 7010.5 1252.2
		1394.7 7007.5 1252.2
	elbow 2.0 1394.7 6834.0 1252.2 1394.7 6837.0 1252.2
		1394.7 6837.0 1249.2
	(10-204-1 10-P-106C/IN 2.0 1389.2 6783.0 1214.5
		elbow 2.0 1391.7 6783.0 1214.5 1394.7 6783.0 1214.5
			1394.7 6786.0 1214.5
		tee (10-204-2 10-204-1 2.0 1392.2 6819.18 1214.5
			10-P-106B/IN 2.0 1389.2 6819.18 1214.5)
			2.0 1394.7 6816.7 1214.5 1394.7 6819.18 1214.5
			1394.7 6821.7 1214.5
		tee 10-204 2.0 1394.7 6834.5 1214.5 1394.7 6837.0 1214.5
			1394.7 6839.5 1214.5
		elbow 2.0 1394.7 6852.4 1214.5 1394.7 6855.4 1214.5
			1391.7 6855.4 1214.5
		10-P-106A/IN 2.0 1389.2 6855.4 1214.5)
	2.0 1394.7 6837.0 1217.0)
Line 10-204 goes to a triplet of pumps through header 10-204-1. The first tee on the header goes to a branch (10-204-2) that goes to the middle pump nozzle. The second tee on the header goes back to the main line.

Multiple Origins – Group of 4

(10-105 8 S2S DW IH 1.0
	(10-105-1 10-P-102B/OUT 6.0 1180.56 6840.108 1233.36
		elbow 6. 1180. 6840. 1281. 1180. 6840. 1290. 1171. 6840. 1290.
			tee (10-105-3 10-P-102A/OUT 6. 1075. 6840. 1233.
					10-105-1 6. 1075. 6840. 1284.)
				6. 1081. 6840. 1290. 1075. 6840. 1290. 1069. 6840. 1290.
			tee 10-105 6. 1021. 6840. 1290. 1015. 6840. 1290.
					1010. 6840. 1290.
			tee (10-105-2 10-P-103B/OUT 8. 956. 6840. 1228.
					10-105-1 8. 956. 6840. 1284.)
				6. 961. 6840. 1290. 956. 6840. 1290. 950. 6840. 1290.
		elbow 8. 870. 6840. 1290. 858. 6840. 1290. 858. 6840. 1278.
					10-P-103A/OUT 8. 858. 6840. 1228.)
				8. 1015. 6840. 1295.
elbow 3. 1015. 6840. 1322. 1015. 6840. 1327. 1015. 6835. 1327.
elbow 3. 1015. 6703. 1327. 1015. 6707. 1327. 1015. 6707. 1331.
elbow 3. 1015. 6707. 1367. 1015. 6707. 1363. 1011. 6707. 1363.
elbow 3. 414. 6707. 1363. 418. 6707. 1363. 418. 6707. 1358.
elbow 3. 418. 6707. 1322. 418. 6707. 1327. 418. 6712. 1327.
elbow 3. 418. 6812. 1327. 418. 6808. 1327. 418. 6808. 1322.
elbow 3. 418. 6808. 1214. 418. 6808. 1219. 414. 6808. 1219.
elbow 3. 387. 6808. 1219. 391. 6808. 1219. 391. 6808. 1223.
elbow 3. 391. 6808. 1403. 391. 6808. 1399. 391. 6812. 1398.
10-T-100/A1 3. 391. 6823. 1396.)
Line 105 starts from a header (10-105-1) off four pump nozzles and goes to a tank inlet. The header has three tees: two to branches and one to the main line.

Change in Specification

(80-122 3 CA11 PL IH 1.0 exception 80-P-190/OUT 3.0 3214.0 2270.72 1230.0
wn_flange
wn_flange 3.0 3214.0 2270.72 1230.0 3214.0 2270.72 1230.0
	3214.0 2270.72 1233.5
elbow 3.0 3214.0 2270.72 1284.25 3214.0 2270.72 1288.75
	3214.0 2275.22 1288.75
elbow 3.0 3214.0 2345.0 1288.75 3214.0 2349.5 1288.75
	3214.0 2349.5 1293.25
elbow 3.0 3214.0 2349.5 1356.25 3214.0 2349.5 1360.75
	3214.0 2354.0 1360.75
elbow 3.0 3214.0 2392.0 1360.75 3214.0 2396.5 1360.75
	3214.0 2396.5 1365.25
tee 80-123 3.0 3214.0 2396.5 1385.5 3214.0 2396.5 1388.875
	3214.0 2396.5 1392.25
elbow 3.0 3214.0 2396.5 1392.25 3214.0 2396.5 1396.75
	3218.5 2396.5 1396.75
spec-break (class AA11 ins NONE thickness 0.0) 3218.5 2396.5 1396.75
OPC-15/MS 3.0 3700.0 2396.5 1396.75)

Fenced Exports

You can select to generate an export file for only those pipes contained in a CAD fence. If the fence mode is “INSIDE”, then the export file will only contain the lines completely enclosed by the fence. If the fence mode is “OVERLAP”, then the export file will contain all pipe segments within the fence.

Single Origin Point with Terminus at Fence Boundary

(90-113 1 NA15 CON IS 1.0 ok
80-E-120/TC 1.0 2484.0 2846.375 1344.0
elbow 1.0 2484. 2846. 1346. 2484. 2846. 1347. 2482. 2846. 1347.
elbow 1.0 2433. 2846. 1347. 2432. 2846. 1347. 2432. 2844.875 1347.
elbow 1.0 2432. 2795. 1347. 2432. 2794. 1347. 2432. 2794. 1346.
elbow 1.0 2432. 2794. 1323. 2432. 2794. 1321. 2432. 2792.5 1321.
OPC-FENCE1/MS 1.0 2432. 2536. 1321.)
Line 90-113 was cut by the fence so the AutoRouter created a boundary component to represent the terminus of the pipe.