PlantWise Help

CAD Seed Files

A project may contain any number of seed drawing files for CAD. These files are used to set CAD attributes such as units, level names, colors, reference files, and rendering settings. It is important that the main units specified in the project setup dialog matches the sub-units settings in the seed drawings. If they do not match, the CAD graphics will not be correctly drawn.

Typically, these drawings do not contain any graphic elements as PlantWise generates all model graphics.

Seed files are saved in the project’s msce\ subfolder and can be used for any model in the project.

Seed drawings are assigned when creating a new model. Components in PlantWise are drawn to level names rather than numbers. The level names shown in table below. CAD Level Numbers and Names are provided in the seed files installed with the software. The drawing seed files should contain levels with at least the names shown in the table. You can define the level properties – number, color, line style, line width, etc. – as desired for any or all of these level names.

If PlantWise components are incorrectly drawing in the color set for level number 1 ( for the provided seed files), then it is possible that the level name for the component does not exist in the drawing file.
Level Name Level Name Level Name
1 exception 17 cable 42 floor
2 frozen 18 cable_exception 43 dropZone

(Floor Penetration)

3 process 19 cable_frozen
4 utility 20 proximity 44 verticalChase
5 any 29 interference 45 piperack
6 steam 30 highlight 46 pipesupport
7 condensate 31 tee 47 structure
8 blowdown 32 cv 48 structurePipeway
9 water 33 psv 49 verticalPipeway
10 air 34 flowmeter 50 obstacle
11 firewater 35 reducer 51 road
12 oil 36 spec_breaks 52 accessway
13 gas 37 inlines 53 building
14 chemical 38 struct-mem-label 54 concrete
15 vent_drain 40 equipment ReportingVolume
16 hc 41 eqnozzle RoutingVolume