To Place Wall Pipe
- Open the Standard Preferences dialog and set the pipeline, specification and component values. The Wall Pipe records shipped with OpenPlant Modeler are stored in the EX-OPM spec.
- Select the Wall Pipe option from the Piping gallery.
- When the Spec Record Selection dialog displays, choose a record from the list and click OK.
- Pick the Placement Point (MAIN_PORT OR RUN_PORT) for the pipe in the Place Component dialog.
- In the Operating Conditions tab, enter a value for the Distance to Thrust Collar field.
- Define additional property values for the component as necessary using the fields available.
- Pick a point in the drawing, or snap to an open end of an existing component. An outline of the component displays.
- Pick another point in the drawing to determine the length of the pipe section.
- Right-click to end the procedure or continue picking points in the drawing to route additional pipe segments.
- Right-click to end the current placement procedure.