Grille Properties
Property Name | Description |
---|---|
Air Flow Rate (CFM)
Air Flow Rate Unit |
Positive <numeric value> This property is used by the Analysis tool for calculating upstream air flow rates for connected elements. Grille fittings when used as route openings in the duct sizing, takes the air flow value for calculation. |
Angle 1 | <angle value> between 0° and 90°. |
Angle 2 | <angle value> between 0° and 90°. |
Auto Size | 1-symprop 2-prop 3-sym 4-custom |
Bar Thickness |
Positive <numeric value> |
Bottom Distance | Positive < numeric value> |
Damper | Angle | <angle value> between 0° and 90° The With Damper property must be set to true for Damper Angle property to be effective. |
Damper | Thickness | Positive <numeric value> |
Dimension | Frame Thickness | Positive <numeric value> |
Horizontal | true false |
Inner Depth | Positive <numeric value> |
Inner Diameter | Positive <numeric value> |
Inner Width | Positive <numeric value> |
Inside Depth | Positive <numeric value> |
Inside Width | Positive <numeric value> |
Mesh Diameter | Positive <numeric value> |
No. of Bars | <integer> |
No. of Horizontal Bars | <integer> |
No. of Vertical Bars | <integer> |
Outer Diameter | Positive <numeric value> |
Outlet pressure (in. wg) | Positive <numeric value> |
Side | Positive <numeric value> |
Side Distance | Positive <numeric value> |
Mesh Horizontal Spacing | Positive <numeric value> |
Mesh Vertical Spacing | Positive <numeric value> |
No. of Slots | <integer> |
No. of Strips | <integer> |
Slot Thickness | Positive <numeric value> |
Strip Thickness | Positive <numeric value> |
Thickness | Positive <numeric value> |
With Damper |
|
Property Option menus are available to assist in making some property entries.