Benchmark - Top Edge Steel tab

Used to set the vertical benchmark with reference to the shape edge. The display for the alignment symbol for the upper edge of the component is set here.
SettingDescription
End Offset Sets the distance between the insertion point of the symbol and the left lower edge of the shape.
Offset Sets the distance between the insertion point of the symbol and the upper edge of the shape.
Colour Sets the color of the symbol for vertical column as color number. Alternatively, the folder icon next enables selecting a desired color from color picker.
Symbol When checked, displays the default built-in display types in the select list for assigning a Vertical benchmark symbol.
  • Symbol selection – Sets one of the symbols from the list of available symbol display types.
  • Symbol Size – Sets the size of the symbol display.
Cell When checked, allows assigning vertical benchmark using the external cells, instead of the Symbol display types.
  • Only cells from drawing – When checked, lists only cells currently available in the drawing. When unchecked, all cells available in the cell path are listed in the Cell selection list.
  • Scale –Sets the scaling for the cell symbol.
  • Cell Selection – Lists the cells available in the cell path to be assigned as Vertical benchmark, or those in the drawing when Only cells from drawing is set.