MicroStation CONNECT Edition Help

To Add Conditions to a Display Rule

  1. In the Display Rules dialog, click the Condition cell of the display rule.

    The Condition Editor dialog opens.

  2. In the Condition Editor dialog, click the Pick property drop-down list.

    You will see two drop-down menus, one for the available classes of elements and another for available properties.

  3. (Optional) Choose from Show classes for available elements, Show classes for selcted elements and Show all schema classes to view the desired class groups.

  4. Select the desired class from the drop-down list.

    The related host properties will display in the Properties drop-down list.

  5. Do one of the following:

    Expand the desired host property to view the types, categories and finally the properties and select the desired property.

    or

    Enter the name of the property in the Search field and select the desired property from the search results. You can also search for desired classes by their name.



  6. Select the desired comparison operator and then select the value.


  7. Do one of the following:

    In the right-side drop-down list, enter or select the value against which you want to compare the property.



    or

    Turn on Toggle between value and property comparison and select the desired property from the right-side drop-down list.



  8. (Optional) To add another criteria, click Add New Criteria and repeat steps 3 to 7 for the new criteria.
  9. (Optional) In the Description field, rename the description of the condition.
  10. Click OK.

    The condition for the display rule displays in the Condition cell in the Display Rules dialog.