EX. To assign the connection tag types to beam ends
-
Select both beams 5 and 6.
Tip: Press Shift+B to display the beam numbers.
-
On the
Beam Tools ribbon tab, select the
Assign tool in the
Connection Tags group.

The Assign Connection Tags and New Connection Tag dialogs open. -
In the
New Connection Tag dialog, select the options to
generate the tags:
- Select EM from the Select Tags drop-down list.
- Select both Start and End options for the Location.
- Click Assign.
The dialog closes and the two tags are added to the Assign Connection Tags dialog, assigned to the members.Note: There are two tags generated, one for the beam start and another for the beam end. - Click Close on the Assign Connection Tags dialog.