A linear, static
analysis is required for this model. You can also instruct
STAAD.Pro to provide a static equilibrium
report.
The STAAD input file commands
generated are:
PERFORM ANALYSIS PRINT STATICS CHECK
On the
Analysis and Design ribbon tab, select the
Analysis Commands tool in the
Analysis Data group.
The
Analysis/Print Commands dialog
opens.
Tip: If the
Analysis/Print Commands dialog
does not open automatically, then click
Define Commands in the
Analysis - Whole Structure dialog.
In the
Analysis/Print Commands dialog,
select the
Perform Analysis tab.
Select the
Statics Check option.
Note: In response to
this option, a report consisting of the summary of applied loading and summary
of support reactions, for each load case, will be produced in the STAAD output
file.
Click
Add.
Tip: The
command is added to the list of commands outlined in the
Analysis - Whole Structure dialog
on the right-hand side of the window. The command has a green checkmark to
indicate that it is valid. You can review the outline of the command input
structure here.
Click
Close.
Tip: Remember to save your work by either
click
Save on the
File ribbon tab , the