T.2 Assign loads to load cases
-
On the
Spreadsheet ribbon tab, select the
Load Cases tool in the
References group.
The Load Cases spreadsheet opens. - For Load 1:
- Select the beam members (M2 and M5).
- Add the uniform distributed dead load:
- Create the live load group: The live load case is added and selected as the active load case as indicated in the application status bar.
- Repeat steps 3 and 4 except to add a uniform distributed load of -600 kg/m (in the Global Y direction) to the beam members (M2 and M5).
- Repeat steps 5 and 6 except to add a Load case 3 with a description of Wind Load and type of Wind. This load group will have the following to load items:
As this model uses a second-order, P-Delta analysis, load
combinations are not recommended. Instead, repeat loads will be used
to combine the load cases so that the combinations are processed by the
analysis engine directly. These Repeat loads will be added in the Analytical
Modeling workflow.
Refer to TR.37.2 P-デルタ解析オプション for further details on load types appropriate for P-Delta analysis.