D3.C.7 Composite Sections
D3.C.7.1 Wide Flange Composite
Using the standard definition of I sections in WIDE FLANGE, 4 additional values can now be provided. The first is the width of concrete to the left of center of the steel web (b1). The second is the concrete width to the right (b2). The third is the concrete depth (d1) to be considered. The last is the modular ratio. The above values are accepted in the program by adding a '-' at the first position on the first line of data. The program now awaits four extra values on line 2 as described above. If (-) is provided on the second line the program requires another 2 breadths + 1 thickness for the bottom plate.
D3.C.7.3 Example
UNIT CM WIDE FLANGE C45752 -66.5 44.98 .76 15.24 1.09 21345 645 21.3 34.185 33.223 150 150 30 10 ISECTION PG9144 -92.05 2.15 92.05 42.05 3.66 42.05 3.66 197.9 153.9 1730 40 40 12 1
The larger British sections have been coded as USER TABLES under wide flange and are available on request to any existing user. Please note however that composite design is not available in this portion of STAAD.