M. To define primary load type
To define or change the load type specified for a primary load case, use the following procedure.
-
On the
Loading ribbon tab, select the
Primary Load
Type tool in the
Load Generation group.
The Define Load Type dialog opens. - For each primary load case, select the Type from the drop-down list in the cell.
- (Optional) For Live or Roof Live load types, check the Reducible-IBC 2003 if this particular load is considered a reducible live load per IBC.
- Repeat steps 2 and 3 for all primary load cases.
- Click OK.