STAAD.Pro Help

P. Soft Story table

The program will check if there are any soft stories in the structure and will display any detected soft story and the direction in this table. These stories will also be highlighted in the active View window. A soft story is defined as a story that has a stiffness in a particular direction that is less than 70% of the stiffness of the story above.

Opens when the Eurocode 8 | Stiffness Checks page is selected.