D10.B.5 Member in Axial Tension

The criteria governing the capacity of tension members is based on two limit states. The limit state of yielding in the gross section is intended to prevent excessive elongation of the member. The second limit state involves fracture at the section with the minimum effective net area. The net section area may be specified by the user through the use of the parameter NSF ( D10.B.11 Design Parameters), that always refers to the gross section. STAAD calculates the tension capacity of a given member based on these two limit states and proceeds with member selection or code check accordingly. 

In addition to the tension resistance criterion, the user defines if tension members are required to satisfy slenderness limitations which are a function of the nature of use of the member (main load resisting component, bracing member, etc.). In both the member selection and code checking process, STAAD immediately does a slenderness check on appropriate members before continuing with other procedures for determining the adequacy of a given member.