STAAD.Pro Help

D1.G.3 Input Specification

A typical set of input commands for STAAD.Pro timber design per AITC 1984 is listed below:

UNIT KIP INCH
PARAMETER
CODE TIMBER
GLULAM  1:16F-V3-DF/DF MEMB 1 TO 14
GLULAM  1:24F-V5-SP/SP MEMB 15 TO 31
GLULAM  20F-V1-DF/WW MEMB 32 TO 41
LAMIN  1.375 LY 168.0 MEMB 5 9 15 TO 31
LZ  176.0 MEMB 1 TO 4 6 7 8 10 TO 14
LUZ 322.6 ALL
LUY 322.6 ALL
WET  1.0 ALL
CDT  1.33
NSF  0.85
BEAM  1.0 ALL
CHECK  CODE 1 TO 14
SELECT  MEMB 15 TO 31

D1.G.3.1 Explanation of Input Commands and Parameters

Specify PARAMETER and then CODE TIMBER to start TIMBER DESIGN before specifying the input parameters. The user must provide the timber grade (GLULAM GRADE) for each member he intends to design. The parameters can be specified for all or specified list of members. If a parameter is not specified, the default value is assigned to it. See following INPUT PARAMETERS LIST TABLE for description and default values of the parameters.

D1.G.3.2 Glulam Grade and Allowable Stresses from Table

The allowable stresses for GLULAM members are read in from Table-1 and Table-2 of AITC for design values for Structural Glued Laminated Timber. The structural members are to be specified in the following manner:

AITC Table-1 glulam members

AITC Table-2 glulam members

For TABLE-2 members, the applicable stress values are selected based on the depth and the number of laminations.