STAAD.Pro Help

D1.F.5.1 Strength Design

All column designs will be based on a uniform distribution of reinforcement around the column perimeter. The design options to control a column design will be based on the CRDO parameter setting.

Column resistance is calculated based on strain compatibility and interaction surface calculations.

The following conditions should be checked (10.5.1.1)
  • ϕPn ≥Pu
  • ϕMn ≥ Mu
  • ϕVn ≥ Vu
  • ϕTn ≥ Tu

ϕPn ≥ Pu

ϕMn ≥ Mu

ϕVn ≥ Vu

ϕ Tn ≥ Tu

Where the nominal axial compressive strength, Pn , shall not exceed Pn,max in accordance with Table 22.4.2.:
  • Pn,max = 0.80 Po for ties
  • Pn,max = 0.85 Po for spirals
  • Po = 0.85 f´c (Ag -Ast) + fyAst)
where
Ast
=
the total area (of nonprestressed) longitudinal reinforcement
Ag
=
the gross area of the concrete section
c
=
the specified compressive strength of concrete
fy
=
the specified yield strength of passive reinforcement
Mn
=
the nominal flexural strength
Vn
=
the nominal shear strength
Tn
=
the nominal torsional moment

The design is performed in two steps considering the longitudinal reinforcement design for axial-bending in an initial step, and the shear and torsion design including the longitudinal reinforcement for torsion tension in a latter pass together with the transverse design.

The minimum area of longitudinal reinforcement is taken as 0.01Ag and the maximum as 0.08Ag. In agreement with the commentary a warning is triggered when the reinforcement ratio is over 4 percent due to possible lap splices zones.