D14.C.7 Design Parameters

The design parameters outlined in table below may be used to control the design procedure. These parameters communicate design decisions from the engineer to the program and thus allow the engineer to control the design process to suit an application's specific needs.

The default parameter values have been selected such that they are frequently used numbers for conventional design. Depending on the particular design requirements, some or all of these parameter values may be changed to exactly model the physical structure.

Note: Once a parameter is specified, its value stays at that specified number until it is specified again. This is the way STAAD.Pro works for all codes.
Table 1. South African Steel Design Parameters
Parameter Name Default Value Description
CODE -

Must be specified SANS10162-1: 2011.

Design code to follow. See TR.48.1 Parameter Specifications.

BEAM 0

0 - Perform design at ends and those locations specified in the section command.

1 - Perform design at ends and 1/12th section locations along member length.

CAN 0

Deflection check for cantilever members.

  • 0 - False
  • 1 - True
CB 1.0

Greater than 0.0 and less than 2.5,Value of ω2 (C1.13.6) to be used for calculation

Equal to 0.0: Calculate ω2

CMY 1.0 Values between 0.4 – 1 used for ω1y (C1.13.8.5). Input beyond the values consider as 1.
CMZ 1.0 Values between 0.4 – 1 used for ω1z (C1.13.8.5). Input beyond the values consider as 1.
DFF 0 Default is 0 indicating that deflection check is not performed
DJ1 0 Start node of physical member for determining deflected pattern for deflection check and should be set along with DFF parameter
DJ2 0 End node of physical member for determining deflected pattern for deflection check and should be set along with DFF parameter
DMAX 1,000 Maximum allowable depth
DMIN 0 Minimum required depth
FU 345 Mpa Ultimate strength of steel
FYLD 300 Mpa Yield strength of steel
KT 1.0 K value for flexural torsional buckling
KY 1.0 K value in local Y-axis, usually minor axis
KZ 1.0 K value in local Z-axis, usually major axis
LT Member length Length for flexural torsional buckling
LY Member length Length in local Y axis for slenderness value KL/r
LZ Member length Length in local Z axis for slenderness value KL/r
MAIN 0

Flag for controlling slenderness check

  • 0 - For Check for slenderness.
  • 1 - For Do not check for slenderness
NSF 1.0 Net section factor for tension members              
RATIO 1.0

Permissible ratio of applied load to section capacity

Used in altering the RHS of critical interaction equations

SSY 0

Sidesway parameter

  • 0 - Sideway about local Y-axis.
  • 1 - No sideway about local Y-axis.
SSZ 0

Sidesway parameter

  • 0 - Sideway about local Z-axis.
  • 1 - No sideway about local Z-axis.
STIFF Member length Center-to-center distance between transverse web stiffeners.
TRACK 0

Track parameter

  • 0. Print the design output at the minimum detail level.
  • 1. Print the design output at the intermediate detail level.
  • 2. Print the design output at maximum detail level
UNB Member Length Unsupported length in bending compression of bottom flange for calculating moment resistance
UNT Member Length Unsupported length in bending compression of top flange for calculating moment resistance