STAAD.Pro Help

V. IS456 2000-Axially Loaded Square Column

Verify the designed results produced by the program with hand calculated design results for an axially loaded square column section as per IS456:2000.

Details

The fixed-base, 2.5 m column is subjected to axial force of 3,300 kN. The section is 500mm x 500mm. The concrete strength is 25 N/mm2 and the yield strength of steel is 415 N/mm2. Use a clear cover of 40 mm. The main reinforcement is 20 mm and the lateral ties are 8 mm.

Validation

Slenderness Ratio

From Table. 28 Clause E-3 of IS 456 : 2000, the effective length of the compression member:

(Leff ) = 2 × L = 2 × 2,500 = 5,000 mm

Least lateral dimension of column = (5,000/500) = 10 < 12

Large lateral dimension of column = (5,000/500) = 10 < 12

So, we can consider and design as a short column.

Check for Minimum Eccentricity of Column

As per Clause 25.4 of IS 456 : 2000, calculate the minimum eccentricity:

For Depth, emin = (2,500/500) + (500/30) = 21.7 mm > 20 mm. (OK)

For Width emin = (2,500/500) + (500/30) = 21.7 mm > 20 mm. (OK)

Hence Minimum Eccentricity is ok.

Check for Maximum Eccentricity of Column

As per Clause 39.3 of IS 456 : 2000 calculate the maximum eccentricity:

For Depth emax = 0.05 × 500 = 25 mm. Hence, emin < emax (OK)

For Width emax = 0.05 × 500 = 25 mm. Hence, emin < emax (OK)

Hence Maximum Eccentricity is ok.

Design for Flexure

Gross Area of Column, Ag = 500 × 500 = 25 × 104 mm2 .

Area of Concrete, Ac = Ag – Asc = 25 × 104 - Asc

Area of Longitudinal Reinforcement, Asc = Pu = 0.4 × fck × Ac + 0.67 × fy × Asc

3,300 × 103 = 0.4 × 25 [ Ag - Asc ] + 0.67 × 415 × Asc

3,300 × 103 = 0.4 × 25 [ 25 × 104 - Asc ] + 0.67 × 415 × Asc

2,985 mm2 .

Let assume 25 mm dia bar. So, Ast = (3.14/4) × 252 = 490.3 mm2 .

Nos. of Bars will be = (2,985/490.3) = 6.1 ≈ 8 Nos

So, the actual reinforcement will be = 8 × (3.14/4) × 252 = 3,925 mm2

As per Clause 26.5.3.2 (c) of IS 456 : 2000 Bar Diameter of Lateral Ties:

¼ × Main Bar dia = ¼ × 25 = 6.3 mm

So, Provide 8 mm dia. bar for lateral ties.

As per Clause 26.5.3.2 (c) of IS 456 : 2000 Pitch of Lateral Ties:

  • Least lateral dimension = 500 mm
  • 16 × 25 = 400 mm
  • 300 mm

Provide 8 mm dia. bar @ 300 mm for lateral ties.

Results

Result Type Reference STAAD.Pro Difference Comments
Reqd. area of steel (mm2) 2,985 2,984.52 negligible  
Spacing of rectangular ties reinforcement (mm) 300 300 none  

STAAD.Pro Input

The file C:\Users\Public\Public Documents\STAAD.Pro CONNECT Edition\Samples\ Verification Models\10 Concrete Design\India\IS456 2000-Axially Loaded Square Column.STD is typically installed with the program.

STAAD SPACE
START JOB INFORMATION
ENGINEER DATE 16-Aug-20
END JOB INFORMATION
INPUT WIDTH 79
UNIT METER KN
JOINT COORDINATES
1 0 0 0; 2 0 2.5 0;
MEMBER INCIDENCES
1 1 2;
DEFINE MATERIAL START
ISOTROPIC CONCRETE
E 2.17184e+07
POISSON 0.17
DENSITY 23.5616
ALPHA 1e-05
DAMP 0.05
TYPE CONCRETE
STRENGTH FCU 27579
END DEFINE MATERIAL
MEMBER PROPERTY AMERICAN
1 PRIS YD 0.5 ZD 0.5
CONSTANTS
MATERIAL CONCRETE ALL
SUPPORTS
1 FIXED
LOAD 1 LOADTYPE Dead  TITLE LOAD CASE 1
JOINT LOAD
2 FY -3300
PERFORM ANALYSIS PRINT ALL
START CONCRETE DESIGN
CODE INDIAN
CLEAR 0.04 ALL
ELZ 2 ALL
ELY 2 ALL
FC 25000 ALL
FYMAIN 415000 ALL
MAXMAIN 25 ALL
MAXSEC 8 ALL
MINMAIN 25 ALL
MINSEC 8 ALL
TRACK 2 ALL
DESIGN COLUMN 1
END CONCRETE DESIGN
FINISH

STAAD.Pro Output

            =========================================================
            IS 456 - 2000   C O L U M N   D E S I G N   R E S U L T S
            =========================================================
   ============================================================================
                IS-456    L I M I T    S T A T E    D E S I G N
            C O L U M N   N O.      1  D E S I G N   R E S U L T S
         M25                    Fe415 (Main)               Fe415 (Sec.)
   LENGTH:  2500.0 mm   CROSS SECTION:  500.0 mm X  500.0 mm  COVER: 40.0 mm
   ** GUIDING LOAD CASE:    1 END JOINT:     1  SHORT COLUMN
   DESIGN FORCES (KNS-MET)
   -----------------------
   DESIGN AXIAL FORCE (Pu)             :    3300.00
                                            About Z            About Y
   INITIAL MOMENTS                     :       0.00               0.00
   MOMENTS DUE TO MINIMUM ECC.         :       0.00               0.00
   SLENDERNESS RATIOS                  :     -                  -     
   MOMENTS DUE TO SLENDERNESS EFFECT   :     -                  -     
   MOMENT REDUCTION FACTORS            :     -                  -     
   ADDITION MOMENTS (Maz and May)      :     -                  -     
   TOTAL DESIGN MOMENTS                :       0.00               0.00
   REQD. STEEL AREA   :     2984.52 Sq.mm.
   REQD. CONCRETE AREA:   247015.48 Sq.mm.
   MAIN REINFORCEMENT : Provide   8 - 25 dia. (1.57%,   3926.99 Sq.mm.)
                        (Equally distributed)                   
   TIE REINFORCEMENT  : Provide  8 mm dia. rectangular ties @ 300 mm c/c
   SECTION CAPACITY BASED ON REINFORCEMENT REQUIRED (KNS)
   ------------------------------------------------------
   Puz :   3300.00 KNS
      STAAD SPACE                                              -- PAGE NO.    6
   SECTION CAPACITY BASED ON REINFORCEMENT PROVIDED (KNS)
   ------------------------------------------------------
   END JOINT:     1 Puz :   3552.63 KNS   IR:0.93
   END JOINT:     2 Puz :   3552.63 KNS   IR:0.93
   ============================================================================
   ********************END OF COLUMN DESIGN RESULTS********************