STAAD.Pro Help

AD.2006.1.4 Persistency of Parameters User to Generate ASCE Wind Load in STAAD Input File

In the past, once the wind load as per the ASCE-7 code was generated automatically using the wind load generator, no information about the parameters was retained by STAAD. So, there was no way to check the parameters, based on which the generation was done. Moreover, if any modification was required at a later stage, all the parameters had to be defined afresh. Automatic wind load generation feature has now been enhanced and the parameters can now be saved as part of the STAAD.Pro model.

Special tag based commands has now been introduced to support saving of ASCE parameters as part of the STAAD input file as shown below.

DEFINE WIND LOAD
   TYPE 1
   INT 0.017517 0.017517 0.0176388 0.017754 0.0178632 -0.0179672 0.0180665 0.0181615 0.0182526 0.0183402  0.018506 -0.0184246 0.0185846 0.0186607 0.0187345 -
   HEIG 0 15 16.1539 17.3077 18.4615 19.6154 20.7692 21.9231 -23.0769 24.2308 25.3846 26.5385 27.6923 28.8462 30
   <! STAAD PRO GENERATED DATA DO NOT MODIFY !!!
   ASCE-7-2002:PARAMS 85.000 MPH 0 2 2 0 0.000 FT 0.000 FT -0.000 FT 1 1 30.000 FT 80.000 FT 60.000 FT 2.000 0.010 0 - 
   0 0 0 0 0.982 1.000 1.150 0.850 0 0 0 0 0.631 0.800 0.550
   !> END GENERATED DATA BLOCK

When a user goes back to the Load page and goes to Definitions | Wind Definitions page and double clicks on the Intensity as shown in the next figure,

the intensity versus height data shows up as shown below.

One can now click on the Calculate as per ASCE-7 button and the parameters that were initially defined are going to appear in the resulting dialog boxes.

Note: Please refer to the example file ASCE_WIND_load_generation.std, which is available under various country folders.