STAAD.Pro Help

D1.L.3.2.3 Compression

The allowable compressive stress for columns, except those fabricated from austenitic stainless steel shall be as required by NF-3322.1(c)(1). The allowable compressive stress for columns fabricated from austenitic stainless steel shall be as required by NF-3322.1(c)(2). The allowable compressive stress for member elements other than columns constructed by any material, including austenitic stainless steel, shall be as required by NF-3322.1(c)(3).

  1. Gross Sections of Columns, except those fabricated of austenitic stainless steel:

    1. On gross section of axially loaded compression members, when (Kl/r) < Cc ,

      F a = F y [ 1 - ( K L / r ) 2 2 C c 2 ] 5 / 3 + 3 ( K L / r ) 8 C c - ( K L / r ) 3 8 C c 3

      Where:

      C c = 2 π 2 E F y
    2. When (Kl/r) > Cc ,

      F a = 12 π 2 E 23 ( K L / r ) 2
    3. When (Kl/r) > 120,

      F a s = F a [ E q . ( a 1 )  or  E q . ( a 2 ) ] 1.6 - ( l 200 r )
  2. Gross sections of columns fabricated from Austenitic Stainless steel:

    1. When (Kl/r) ≤ 120,

      F a = F y ( 0.47 - K L / r 444 )
    2. When (Kl/r) > 120,

      F a = F y ( 0.40 - K L / r 600 )
  3. Member elements other than columns:

    1. For Plate Girder Stiffeners, Fa = 0.60·Fy
    2. For webs of rolled shapes, Fa = 0.75·Fy

The above clauses are applicable only when the width-thickness ratio of the element satisfies all the sub-sections of NF-3322.2(d).

If the above-mentioned clauses are not satisfied,

  1. For un-stiffened compression element, a reduction factor, Qs, is introduced. Detailed values of Qs for different shapes are given in NF-3322.2(e)(2)(a) to NF-3322.2(e)(2)(d).

    In the case for angles or plates projecting from compression members and for projecting elements of compression flanges of girder,

    When 95 / F y / k c < b / t < 195 / F y / k c , Q s = 1.293 - 0.00309 ( b / t ) F y / k c

    When b / t > 195 / F y / k c ,

    Q s = 26 , 200 k c F y ( b / t ) 2

    Where:

    • k c = 4.05 ( h / t ) 0.46 when h/t > 70, otherwise, kc = 1.0.
  2. For stiffened compression element, a reduced effective width, be, is introduced.

    1. For the flanges of square and rectangular sections of uniform thickness:

      b e = 253 t f [ 1 - ( 50.3 ( b / t ) f ) ] b
    2. For other uniformly compressed elements:

      b e = 253 t f [ 1 - ( 44.3 ( b / t ) f ) ] b

    Consequently, a reduction factor, Qa, equal to the effective area divided by the actual area is introduced.

    Combining both these factors, allowable stress for axially loaded compression members containing stiffened or un-stiffened elements shall not exceed

    F a = F y Q s Q a [ 1 - ( K L / r ) 2 2 C c 2 ] 5 / 3 + 3 ( K L / r ) 8 C c - ( K L / r ) 3 8 C c 3

    Where:

    C c = 2 π 2 E Q s Q a F y
The section is also checked that the stress is less than 2/3× the critical buckling stress, which is taken as the Euler critical buckling load divided by the cross sectional area:
F = 2 3 P cr A
where
Pcr
=
the Euler critical buckling load of the column: π 2 E I ( K L ) 2