STAAD.Pro Help

D8.A.5 Code Checking and Member Selection

Both code checking and member sSelection options are available for the IS 800: 2007 code.

Refer to D1.B.1.3 Code Checking for general information on Code Checking. Refer to TR.49 Code Checking Specification for details the specification of the Code Checking command.

Refer to D1.B.1.4 Member Selection for general information on Member Selection. Refer to TR.49.1 Member Selection Specification for details the specification of the Member Selection command.

D8.A.5.1 Example 1

Commands for code checking:

UNIT NEWTON METER
PARAMETER 1
CODE IS800 LSD
ALPHA 0.7 ALL
CAN 1 MEMB 2
PSI 0.8 MEMB 2
TMAIN 350 MEMB 2
TRACK 2 MEMB 2
CHECK CODE MEMB 2

D8.A.5.2 Example 2

Commands for member selection:

UNIT NEWTON METER
PARAMETER 1
CODE IS800 LSD
MAIN 160 MEMB 7
KY 0.8 MEMB 7
KZ 0.9 MEMB 7
FYLD 350 ALL
SELECT ALL