D4.B.8 Code Checking

The purpose of code checking is to check whether the provided section properties of the members are adequate. The adequacy is checked as per the CAN/CSA-S16-01  requirements.

Code checking is done using forces and moments at specified sections of the members. If the BEAM parameter for a member is set to 1, moments are calculated at every twelfth point along the beam. When no sections are specified and the BEAM parameter is set to zero (default), design will be based on member start and end forces only. The code checking output labels the members as PASSed or FAILed. In addition, the critical condition, governing load case, location (distance from the start joint) and magnitudes of the governing forces and moments are also printed. The extent of detail of the output can be controlled by using the TRACK parameter.

Example of commands for CODE CHECKING:

UNIT NEWTON METER
PARAMETER
CODE CANADIAN
FYLD 330E6 MEMB 3 4
NSF 0.85 ALL
KY 1.2 MEMB 3 4
UNL 15 MEMB 3 4
RATIO 0.9 ALL
CHECK CODE MEMB 3 4