STAAD.Pro Help

D4.B.10 Tabulated Results of Steel Design

Results of code checking and member selection are presented in a tabular format. The term CRITICAL COND refers to the section of the CAN/CSA-S16-01 specification which governed the design.

If the TRACK parameter is set to 1.0, factored member resistances will be printed. Following is a description of some of the items printed.

CR
Factored compressive resistance
TR
Factored tensile resistance
VR
Factored shear resistance
MRZ
Factored moment resistance (about z-axis)
MRY
Factored moment resistance (about y-axis)

Further details can be obtained by setting TRACK to 2.0.

CR1
CAPACITY (Cr) PER 13.8.2(a)
CR2
CAPACITY (Cr) PER 13.8.2(b)
CRZ
SEE 13.8.2(b) for uniaxial bending (called CRX in that Clause)
CTORFLX
Capacity in accordance with 13.8.2(c)