STAAD.Pro Help

TR.19.11 Using Reference Table Files

The User-Provided Steel Tables may be created and maintained as separate files. The same files may be used for all models using sections from these tables. These files should reside in the same directory where the input file is located.

START USER TABLE
TABLE  1 TFILE1 
TABLE  2 TFILE2 
END

Where TFILE1 and TFILE2 are names of files which must be created prior to running STAAD, and where the file TFILE1 contains the following:

On each file the first table should contain a UNITS command.

UNIT  . . .
WIDE FLANGE
W14X30
8.85  13.84  .27  6.73  .385  291.  19.6  .38  0  0
W21X50
14.7  20.83  .38  6.53  .535  984  24.9  1.14  7.92  0
W14X109
32.  14.32  0.525  14.605  .86  1240  447  7.12  7.52  0

and the file TFILE2 contains:

UNIT  . . .
ANGLES
L25255
2.5  2.5  .3125  .489  0  0
L40404
4.  4.  .25  .795  0  0