STAAD.Pro Help

D4.B.7 Design Parameters

The design parameters outlined in Table 3B.1 may be used to control the design procedure. These parameters communicate design decisions from the engineer to the program and thus allow the engineer to control the design process to suit an application's specific needs.

The default parameter values have been selected such that they are frequently used numbers for conventional design. Depending on the particular design requirements, some or all of these parameter values may be changed to exactly model the physical structure.

Note: 一度パラメータを設定すると、その値は再度設定されるまで設定されたその数のままです。これはSTAAD.Proで、すべてのコードに対してあてはまります。
Table 1. Canadian Steel Design CSA-S16-01 Parameters
Parameter Name Default Value Description
CODE -

Must be specified as CANADIAN 2001.

準拠する設計コード。「TR.48.1 パラメータの設定」を参照してください。

BEAM 1.0

0.0  =  design only for end moments and those at locations specified by SECTION command.

1.0  =  Perform design for moments  at twelfth points along the beam.

CB 1.0

Greater than 0.0 and less than  2.5 : Value of Omega_2 (Cl.13.6) to be used for calculation.

Equal to 0.0 : Calculate Omega_2

CMY 1.0

1.0  =  Do not calculate Omega-1 for local Y axis.

2.0 = Calculate Omega-1 for local Y axis.

Used in Cl.13.8.4 of code

CMZ 1.0

1.0  =  Do not calculate Omega-1 for local Z axis.

2.0 = Calculate Omega-1 for local Z axis.

Used in Cl.13.8.4 of code

DFF None(Mandatory for  deflection check) "Deflection Length"/Maxm. Allowable local deflection.

使用性の荷重エンベロープを使用したたわみチェックについては、「TR.40 荷重エンベロープ」を参照してください。

DJ1 Start Joint of member Joint No. denoting start point for calculation of “deflection length”
DJ2 End Joint of member Joint No. denoting end point for calculation of “deflection length”
DMAX 45.0 in. Maximum allowable depth (Applicable for member selection)
DMIN 0.0 in. Minimum required depth (Applicable for member selection)
FU 345.0 MPa Ultimate strength of steel.
FYLD 300.0 MPa Yield strength of steel.
KT 1.0 K value for flexural torsional buckling.
KY 1.0 K value for general column flexural buckling about the local Y-axis. Used to calculate slenderness ratio.
KZ 1.0 K value for general column flexural buckling about the local Z-axis. Used to calculate slenderness ratio.
LT Member Length Length for flexural torsional buckling.
LY Member Length Length for general column flexural buckling about the local Y-axis. Used to calculate slenderness ratio.
LZ Member Length Length for general column flexural buckling about the local Z-axis. Used to calculate slenderness ratio.
MAIN 0.0

0.0  =  Check slenderness ratio against the limits.

1.0= Suppress the slenderness  ratio check.

2.0 = Check slenderness ratio only for column buckling, not for web (See Section 3B.6, Shear)

NSF 1.0 Net section factor for tension members.
RATIO 1.0 Permissible ratio of actual load effect to the design strength.
SHEAR 1 Shear stress calculation option.

0) = compute the actual shear stress using VQ/Ib

1) = compute the actual shear stress using V/(Ay or Az)

SSY 0
  • 0 = Sway or Unbraced along local Y axis
  • 1 = Braced along local Y axis
This parameter is required to choose the proper value of U1y which is used to determine the cross-sectional strength, overall member strength and lateral torsional buckling strength.
SSZ 0
  • 0 = Sway or Unbraced along local Z axis
  • 1 = Braced along local Z axis
This parameter is required to choose the proper value of U1z which is used to determine the cross-sectional strength, overall member strength and lateral torsional buckling strength.
TRACK 0.0

0.0 = Report only minimum design results.

1.0 = Report design strengths also.

2.0 = Provide full details of design.

UNB Member Length Unsupported length in bending compression of the bottom flange for calculating moment resistance.
UNT Member Length Unsupported length in bending compression of the top flange for calculating moment resistance.