Smart Connections
Used to assign smart connection templates to selected joints. A "smart" connection template contains parametric rules defined in a macro which allows characteristics of the connection to be modified (within limits) in order to achieve code compliance. A joint selection set that is to use a Smart connection can only specify a single smart connection definition.
Setting | Description | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Design | Select the design code to be used. The field is populated with the default code selected in the RAM Settings dialog. | ||||||||||
Seismic Provisions |
(AISC codes only) Select the Consider AISC 341-05 Seismic Provisions option to instruction the program to design the connections per this specification. A gravity load combination must be selected when this option is used. |
||||||||||
Consider Structural Integrity | (BS5950 only) Select this option to include the requirements for structural integrity in the design (Cl 2.4.5.2 BS5950 1:2000). A tie force not less than 75 kN is considered for these verifications. The appendices A to D (BS5950 1:2000) give the required information on the behavior and methodology to resist tying forces in the design. | ||||||||||
Seismic Category | (Base Plate only) Specify the site class which best describes the soil conditions supporting the foundation and base plate. | ||||||||||
Connection types | Select the class of connection to be used from this list. The connection types available depend on the code selected. | ||||||||||
Available list | A list of all available connection templates for the selected connection type are listed here. | ||||||||||
List Operators |
|
||||||||||
Selected list | The connection templates selected for design will be added to the list. | ||||||||||
Design Connections Individually | Select this option to instruct the program to optimize connections at each joint separately, rather than grouping for the worst case among common connections. |