STAAD.Pro Help

Add New Wind Definitions (data) dialog

Used to add wind pressure data or code-specific wind parameters.

Intensity tab

SettingDescription
Select Type Choose the method of specifying wind pressure values from the drop-down:
  • Custom – ASCE 7 or other user-specified wind pressures
    SettingDescription
    Intensity vs. Height table Enter pairs of data for wind pressure at a given height (in the current units).

    Int cells – wind intensities (pressures) in force/area. Up to 100 different intensities can be defined in the input file per type.

    Height cells – corresponding heights in global vertical direction, measured in terms of actual Y (or Z for Z UP ) coordinates up to which the corresponding intensities occur.

    Calculate as per ASCE 7 Opens the ASCE-7 Wind Load dialog, which is used to generate a wind load per the ASCE 7 specification. Input data on the type of structure, surrounding terrain, and wind.
  • SNiP 2.01.07-85 or SP 20.13330.2016 – Russian wind load parameters
    SettingDescription
    Pressure the characteristic value of wind pressure, always positive
    Terrain
    terrain roughness category:
    1. Coastal Zone.
    2. Urban Zone.
    3. Large City.
    Region Wind region as per clause 11.5 of SNiP 2.01.07-85* 2016. This is used to determine the wind pressure in determine the dynamic wind component.
    Delta
    logarithmic decrement of oscillations, Delta (see table 11.5 - Section 11.1.8 for the definition). Typically values are:
    • 0.15 for steel towers, masts, lined chimneys, column means including the ones on the reinforced concrete pedestals
    • 0.3 for reinforced concrete and stone structures as well as for buildings with steel framework if there are walling structures
  • GB 50009-2012 - Chinese wind load parameters
    SettingDescription
    Generate Wind Load Opens the Generate Wind Definition and Wind Load Case for Chinese GB 50009 dialog, which is used to enter code parameters for generating wind intensity values based on the GB 50009 2012 code.

Exposures tab

SettingDescription
Factor

exposure factors.  A value of 1.0 means that the wind force may be applied on the full influence area associated with the joint(s) if they are also exposed to the wind load direction.  Limit: 99 factors.

Note: Note any joint does not have an exposure assigned, the exposure will be taken as 1.0.