STAAD.Pro Help

D3.C.5 Shear Capacity

The shear capacity, as outlined in clause is a function of the limiting shear strength, l, which is dependant on the slenderness ratio. STAAD follows the iterative procedure of appendix G8 to determine the limiting shear strength of the web panel. The shear capacity is then calculated based on the formula given under clause 9.9.2.2.