Units |
Select the units of Tank Weight Force, Fluid Volume, Internal Pressure, and Pressure Load used in tank Loading parameters.
|
Internal Pressure |
Type values for Internal Pressure at both Operating Level (normal conditions) and Test Level in selected units for internal pressure.
|
Tank Weight group |
Specify these values when the Direct Weight Input option is set on Tank Foundation page
.
Setting | Description |
---|
Operating Fluid Weight |
Type a value of total fluid weight under normal operating conditions.
|
Test Fluid Weight |
Type a value of total fluid weight under testing conditions.
|
Liquid Height Units |
Select the units used to enter liquid height parameters.
|
Liquid Height (Operating) |
Type a value of fluid height under normal operating conditions.
|
Liquid Height (Test) |
Type a value of fluid height under testing conditions.
|
|
Fluid Properties group |
Specify these values when the Tank Fluid Volume Input option is set on Tank Foundation page
.
Setting | Description |
---|
Operating Product Volume |
Type the volume of liquid contained in the tank under normal operating conditions.
|
Test Product Volume |
Type the volume of liquid contained in the tank under testing conditions.
|
Specific Gravity of Product |
Type the unit weight of the liquid.
|
|
Pressure Load group |
These define the loads distributed over the roof of the tank.
Setting | Description |
---|
Roof Snow Load |
Type a pressure value for the snow load (if any) on the tank roof.
|
Snow Importance Factor (Isnow) |
Type the importance factor used for the snow load.
|
Miscellaneous Dead Load |
Type the composite dead load on the tank roof (excluding the self weight of the tank roof).
|
Live Load |
Type the composite live load on the tank roof.
|
|