Unit
|
First give the units for three types of dimensions, density, length and stress. |
Concrete and Rebar group |
Setting | Description |
---|
Concrete Unit Weight
|
Specify a density to be used for concrete (wC). |
Fc
|
Specify the ultimate strength of the concrete (f'c). |
Fy
|
Specify the yield strength of steel reinforcing bars (fy). |
Max / Min Bar Spacing
|
Specify the minimum and maximum distances to be allowed between reinforcing bars. |
Max / Min Bar Size
|
Select the minimum and maximum allowed reinforcing bar sizes to be used in the design. |
|
Cover and Soil group |
Setting | Description |
---|
Pedestal Clear Cover
|
Specify clear cover distance between face of pedestal and edge of reinforcing bars. |
Footing Bottom Cover
|
Specify a concrete clear cover distance to be used for the bottom-most layer of footing reinforcement. |
Soil Unit Weight
|
Specify a density to be used for the soil. |
Soil Bearing Capacity
|
Specify the allowable bearing capacity of the soil, in the selected units. |
Soil Depth
|
Specify the depth from soil surface to the top of footing. |
Load Surcharge
|
Specify a surcharge loading above the footing. |
Minimum Permissible Area in Contact With Soil
|
Specify a percentage of area of contact between footing and soil. |
|
Sliding and Overturning group |
Setting | Description |
---|
Coefficient of Friction
|
Specify a coefficient value of friction between the soil and concrete. |
Factor of Safety (Sliding)
|
Specify a factor of safety against sliding. |
Factor of Safety (Overturning)
|
Specify a factor of safety against overturning. |
|
< Previous
|
Steps the Wizard to the previous step.
|
Cancel
|
Exits the Wizard without creating a new Heat Exchanger Footing job.
|
Finish
|
Closes the Wizard and creates the Heat Exchanger Footing job in the current project.
|