Height (z)
|
Height from ground or water surface (m), maximum superstructure height plus substructure height is considered for all spans in calculation. |
Air density
|
The air density (kg/m3) r is calculated using the formula . |
Conversion fact (k0)
|
Conversion factor for recurrence interval of wind velocity design value, for spans less than 40 m we take k0=0.9 if greater or equal we take k0=1. |
Resistance fact (k1)
|
Wind load resistance factor. In normal service period, the superstructure k1 of normal solid web bridge shall be taken as | (4.3.7-4) |
whereB | = | width of bridge (m) | H | = | height of beam (m) | |
Correction fact (k2)
|
Wind velocity correction factor according to height variation considered with degree class of roughness and height of gradient wind as taken from Table 4.3.7-3. |
Topography fact (k3)
|
Topography and geography condition factor, taken from Table.4.3.7-1. |
Gust velocity fact (k5)
|
Gust velocity factor, for Terrain roughness types A and B we have k5 =1.38 and for C and D k5 =1.7. |
Wind velocity
|
Basic design wind velocity in zone where the bridge is located (m/s). Can be adopted according to Appendix B and related data after being checked but not to be less than 0.7m/s; |
Wpt
|
Calculated area load of wind pressure (kN/m2) transverse to the bridge whereV | = | wind velocity | g | = | gravitational acceleration equal to 9.81(m/s2) | |
Consider wind
|
(Yes/No) defines whether the particular wind situation shall be considered or not. |