Action > ElemK
Correction of element stiffness
Supported element types and stiffness components for this action are:
- Beam (with cross section or CS-values, no composite): Ax, Ay, Az, Ix, Iy, Iz
- Cable: Ax
- Static Spring: Ax, Ay, Az, Ix, Iy, Iz
- Compression only Spring: Ax, Ay, Az, Ix, Iy, Iz
- Tension only Spring: Ax, Ay, Az, Ix, Iy, Iz
Setting | Description |
---|---|
Action | Code of the selected Action. It is possible to switch to another action without leaving and re-entering the input function. |
Action will be skipped (Option) | The action will be skipped in the calculation process if the option is selected. |
Input of RmSet name, where the element series is defined, or direct input of the series of elements (i.e.:1,3,1) | |
Factors for normal force and bending stiffness. | |
Factors for shear and torsional stiffness | |
Delta-T | Duration of the Action (not applicable for this action) |
Description | Descriptive text for the selected Action (max. 80 characters) |