RM Analyzer Help

Choice of the characteristic result value

The required result value is specified by the element, the result point in the element, the component of the result vector and the specification, whether this value shall become a maximum or a minimum.

SettingDescription
Element list The required element can be selected in this list.  For better orientation, some basic element parameters such as . element type and start and end node are additionally displayed in the list.
Begin of element / End of Element / Subdivision Switches for selecting the required result point of the Element A subdivision point can only be specified, if an element subdivision has been defined for the selected element (in Structure > Element data and properties)
Note: Subdivision point 0 indicates the element begin,  any value greater or equal to the number of subdivisions indicates the element end point being taken.