Action > FatigSup
FatigSup The action performs a fatigue check for a superposition file (envelope). The envelope must contain the maximum/minimum internal forces for the traffic loads relevant for fatigue. The difference between maximum and minimum is taken as relevant stress range value Delta-sigma.
Setting | Description |
---|---|
Action | Code of the selected Action. It is possible to switch to another action without leaving and re-entering the input function. |
Action will be skipped (Option) | The action will be skipped in the calculation process if the option is selected. |
Superposition file | Name of the superposition file containing the relevant design forces |
Name of list file, where the results of the fatigue check will be written. Default (*): The name of the list file is automatically created: FatiLcName.lst with LcName being the name of the design load case. If there is no input, no list file will be created. | |
Delta-T | Duration of the Action (not applicable for this action) |
Description | Descriptive text for the selected Action (max. 80 characters) |