Action: CabSag
CabSag Input of the element series, for which the correction factor of E-modulus will be input. (cable sagging)
Setting | Description |
---|---|
Action will be skipped (Option) | The action will be skipped in the calculation process if the option is selected. |
Action | CabSag - nonlinearity due sagging of cables can be taken into account by virtual E-Modulus, known as Ernst-Modulus. For its calculation the factor has to be set. |
RmSet || Element: From,To,Step | Input of RmSet name, where the element series is defined resp. Input the series of elements (i.e.:1,3,1) |
Factor | Input the correction factor for E-Modulus: E* = E * Factor |
Delta-T | Duration of the Action (not applicable for this action) |
Description | Descriptive text for the selected Action (max. 80 characters) |