Action: Failure
Stability of the structure will be checked. The reference load case will be in limits of factors increased till failure. The result is maximal loading before the failure. Bisection is used for iteration.
Setting | Description |
---|---|
Action will be skipped (Option) | The action will be skipped in the calculation process if the option is selected. |
Command | This is automatically assigned from the previous selection - it can not be edited in this pad. |
Fact-from,Fact-to,Tol | Increasing factor interval and the failure tolerance |
Reference load case name | Name of increasing load case |
(Variable) | If no further option is set, all load sets will be increased If 'Variable' option is set, only the load sets with the increase switch will be changed |
Output load case | The state before failure is stored to the load case name, defined by user |
List file | The name for the list file. If no input will be made, the list file will not be created! |
Delta-T | Duration of the Action (not applicable for this action) |
Description | Descriptive text for the selected Action (max. 80 characters) |