Template > Combination Table DIN FB
Loading a template combination table according to DIN-FB.
The default names of the load cases and superposition files can be changed directly or by selecting them from the list.
Options: The predefined combination tables either can directly be import into data base or alternatively a TCL file for later import can be generated. It is possible to "Save" all modification in this input pad at any label name. And "Load" will restore this input in a later call of this template.
Abstract of predefined Load-Combinations
Combination I and II - "permanent loads"
- Comb.I: Pk, t=0
- Comb.II: Pk, t=oo
SLS - Combinations III to V - "rare combination"
- Comb.III: Pk, t=0
- Comb.IV: Pk, t=oo
- Comb.V: Pm, t=0, t=oo
SLS - Combination VI - "infrequent combination"
- Comb.VI: Pm, t=0, t=oo
SLS - Combination VII - "frequent combination"
- Comb.VII: Pm, t=0, t=oo
SLS - Combinations VIII to X - "quasi-permanent combination"
- Comb.VIII: Pk, t=0
- Comb.IX: Pk, t=oo
- Comb.X: Pm, t=0, t=oo
ULS - Combinations XI and XII - "characteristic" and "transient design situation"
- Comb.XI: gr1
- Comb.XII: gr2
Combinations XIII and XIV - special combinations
- Comb.XIII: bearing capacity
- Comb.XIV: fatigue